EMC Technology Florida RF Labs

                 

Lab-Flex® S Family

The Lab-Flex® S family is a stranded center conductor version of our popular Lab-Flex® series. They offer high flexure rates and durability over the solid center conductor designs. They are especially well-suited for test set-ups as well as Radar and Antenna systems requiring flexible coaxial interconnects that are being subjected to constant motion.  These assemblies are offered with stainless steel connectors and have the strongest cable to connector termination of all cable types.


The Solder Sleeve Advantage

One advantage of using our Lab-Flex® cables is the cable-to-connector termination utilizing our unique solder sleeves. Common methods of cable terminations such as crimping or clamping the outer cable braids to the connector body does not adequately capture all the of the braid, which can lead to intermittent electrical performance and low connector retention and pull strength. With the Lab-Flex® solder sleeve, both the inner and outer braids are directly soldered with a 360 degree coverage. This feature provides the best braid to connector termination assuring superior electrical performance and mechanical integrity.


Download Overview Sheet
 
Download Datasheet
 

Features:

• Designs up to 65 GHz
• Some designed to exceed 500,000 flexures
• 7 & 19 Strand Copper Conductor versions
• 30% Lower Loss than Solid Dielectrics
• Superior Shielding Effectiveness
• Direct Solder Sleeve to Outer Braids
• Available with Protective Coverings of:
      Weatherization
      Extended Boots
• Phased Matched Sets Available
 

Applications:

• Antenna Systems
• Radar Systems
• Production and Lab Testing
 

Quick Specifications:


Cable Code                       
LAB-FLEX®S
115S
LAB-FLEX®S
180SP
LAB-FLEX®S
235SP
LAB-FLEX®S
335SP
LAB-FLEX®S
490S
Diameter (inches)  0.105 0.180 0.235  0.335  0.490
Frequency, Max (GHz)  65  40  26.5  18  10
Insertion Loss @ 5 GHz (dB/100ft)  59.1  40.0  21.0  15.0  8.9
Electrical Data          
Impedance, nominal  (Ohms)  50 50 50 50 50
Velocity of Propagation (%)  76 78 78 78 80
Shielding Effectiveness, 18 GHz (dB/ft)  >90 >90  >90  >90 >90
Capacitance (pF/ft)  27 27 27.3 27 25.5
Delay (ns/ft)  1.34 1.30 1.30 1.30 1.27
Mechanical Data          
Weight (lbs/100ft)  2.00 3.00 5.50  9.00 19.20
Temperature Range (°C)  -65 to +200 -65 to +85  -65 to +85    -65 to +85   -55 to +200
Minimum Bend Radius (inches)  0.50 0.90 1.10 1.60 2.50
Construction Data          
Inner Conductor
Silver Plated Copper (inches)
Stranded
0.019
 Stranded
0.034
 Stranded
0.048
 Stranded
0.084
 Stranded
0.131
Dielectric
Expanded PTFE (inches)
 0.056  0.097  0.137  0.240  0.360
First Outer Shield
Flat Silver Plated Copper Braid (inches)
 0.062  0.109  0.149  0.249  0.371
Second Outer Shield
Conductive Tape Interlayer (inches)
 0.071  0.125  0.164  0.263  0.376
Third Outer Shield
Round Silver Plated Braid (inches)
 0.087  0.141  .184  0.286  0.400
Jacket Material
O.D. (inches)                               
FEP
0.105
Polyurethane
0.180
Polyurethane
0.235
 Polyurethane
0.335
 FEP
0.490